Wireman · Pool pump won’t run: troubleshooting for electricians · 2023 NEC ·
Pool pump won’t run
Timers and automation, tripped GFCI, capacitor, a jammed impeller and variable-speed drives.
Before you start
How much electrical experience do you have?
This sets how much detail each step shows. You can change it any time.
Showing detail
How it works
A pool pump is usually a single-phase motor, or a variable-speed motor with its own built-in drive. It gets power through a timer or automation system, and current code requires GFCI protection for pool pump motors. Single-speed pumps that hum but don’t turn usually have a failed capacitor or a jammed impeller. Variable-speed pumps have electronics and their own fault indicators, and they often wait for a schedule.
Every question and answer in this guide. Tap “Step by step” to walk through it.
- What does the pump do?
- Nothing, silentIs the breaker or GFCI on, and is the timer or automation calling for the pump?
- GFCI or breaker trippedGround fault in the pump or its wiring
- Timer or schedule was offTimer or schedule
- All on and callingTest: Measure voltage at the pumpExpect: The nameplate voltage (115 V or 230 V), within 10%.
- No voltageTimer, relay or wiring
- Full voltage, single-speed pump silentMotor failure
- Full voltage, variable-speed pump shows a faultVariable-speed pump drive fault
- Hums but doesn’t turnWith power locked out, does the shaft turn by hand?
- Stuck or very stiffJammed impeller or seized bearing
- Turns freelyTest: Test the capacitorExpect: Within the printed tolerance.
- Low, open or bulgingFailed capacitor
- GoodMotor failure
- Trips the GFCI or breakerGround fault in the pump or its wiring
- Nothing, silentIs the breaker or GFCI on, and is the timer or automation calling for the pump?